nanoFramework.Iot.Device.Tsl256x 1.2.869

Prefix Reserved
dotnet add package nanoFramework.Iot.Device.Tsl256x --version 1.2.869
                    
NuGet\Install-Package nanoFramework.Iot.Device.Tsl256x -Version 1.2.869
                    
This command is intended to be used within the Package Manager Console in Visual Studio, as it uses the NuGet module's version of Install-Package.
<PackageReference Include="nanoFramework.Iot.Device.Tsl256x" Version="1.2.869" />
                    
For projects that support PackageReference, copy this XML node into the project file to reference the package.
<PackageVersion Include="nanoFramework.Iot.Device.Tsl256x" Version="1.2.869" />
                    
Directory.Packages.props
<PackageReference Include="nanoFramework.Iot.Device.Tsl256x" />
                    
Project file
For projects that support Central Package Management (CPM), copy this XML node into the solution Directory.Packages.props file to version the package.
paket add nanoFramework.Iot.Device.Tsl256x --version 1.2.869
                    
#r "nuget: nanoFramework.Iot.Device.Tsl256x, 1.2.869"
                    
#r directive can be used in F# Interactive and Polyglot Notebooks. Copy this into the interactive tool or source code of the script to reference the package.
#addin nuget:?package=nanoFramework.Iot.Device.Tsl256x&version=1.2.869
                    
Install as a Cake Addin
#tool nuget:?package=nanoFramework.Iot.Device.Tsl256x&version=1.2.869
                    
Install as a Cake Tool

TSL256x/TSL2560/TSL2561 - Illuminance sensor

TSL2560 and TSL2561 are illuminance sensor. They are light-to-digital converters that transform light intensity to a digital signal output capable of direct I2C (TSL2561) or SMBus (TSL2560) interface. Each device combines one broadband photodiode (visible plus infrared) and one infrared-responding photodiode on a single CMOS integrated circuit capable of providing a near-photopic response over an effective 20-bit dynamic range (16-bit resolution).

Two integrating ADCs convert the photodiode currents to a digital output that represents the irradiance measured on each channel. This digital output can be input to a microprocessor where illuminance (ambient light level) in lux is derived using an empirical formula to approximate the human eye response.

The TSL2560 device permits an SMB-Alert style interrupt, and the TSL2561 device supports a traditional level style interrupt that remains asserted until the firmware clears it.

Documentation

Board

image

Usage

Basic usage

TSL2560 and TSL2561 are designed to have an integration time and a gain for measuring the 2 ADC. The defaults are 402 milliseconds and a normal gain of x1.

The basic usage is the following:

I2cDevice i2cDevice = I2cDevice.Create(new I2cConnectionSettings(1, Tsl256x.DefaultI2cAddress));
Tsl256x tsl256X = new(i2cDevice, PackageType.Other);
tsl256X.IntegrationTime = IntegrationTime.Integration402Milliseconds;
tsl256X.Gain = Gain.Normal;
var lux = tsl256X.MeasureAndGetIlluminance();
Console.WriteLine($"Illuminance is {lux.Lux} Lux");

notes:

  • Be aware, there are 2 types of packaging the CS and the Others T, FN and CL. Refer to the documentation to understand which package you have on the board. This is an argument when creating the sensor as the calculation for the illuminance is different.
  • There are 3 different possible I2C addresses for this device depending on how the address pin is setup:
    • DefaultI2cAddress = 0x39: When address pin is to the ground
    • SecondI2cAddress = 0x29: When address pin is floating
    • ThirdI2cAddress = 0x49: When address pin is to VDD

Check the version

You can determine if you have a TSL2560 or TSL2561 version:

var ver = tsl256X.Version;
string msg = ver.Major & 0x01 == 0x01 ? $"This is a TSL2561, version {ver}" : $"This is a TSL2560, version {ver}";
Console.WriteLine(msg);

Using interruptions

You can set interruptions, you have different possible ones you can set thru the InterruptLevel:

  • OutputDisabled: will disable the interrupt
  • LevelInterrupt: will use the permanent interrupt you'll setup, see right after
  • SmbAlertCompliant: will send an alert on the SMB bus (version TSL2560 only) on address 0b0000_1100
  • TestMode: will generate an interruption for test purpose

The InterruptPersistence will allow you to select a specific timing for the interrupt:

  • EveryAdc: each time you have a measurement
  • AnyValueOutsideThreshold: any time a value will be outside of the setup threshold
  • OutOfRangeXXIntegrationTimePeriods: where XX is from 2 to 15, will interrupt only if the value remains outside more than XX times

The following example shows how to setup a basic interruption using test mode:

Console.WriteLine("Set interruption to test. Read the interrupt pin");
GpioController controller = new();
controller.OpenPin(PinInterrupt, PinMode.Input);
tsl256X.InterruptControl = InterruptControl.TestMode;
tsl256X.Enabled = true;
while (controller.Read(PinInterrupt) == PinValue.High)
{
    Thread.Sleep(1);
}

Console.WriteLine($"Interrupt detected, read the value to clear the interrupt");
tsl256X.GetRawChannels(out ushort ch0, out ushort ch1);

You can setup interruptions on thresholds as well. You first need to setup a threshold and then the type of interruptions.

// Adjust those values with a previous measurement to understand the conditions, find a level where then you can
// hide the sensor with your arm and make it going under the minimum level or vice versa with a lamp
tsl256X.SetThreshold(0x0000, 0x00FF);
tsl256X.InterruptPersistence = InterruptPersistence.OutOfRange06IntegrationTimePeriods;
tsl256X.InterruptControl = InterruptControl.LevelInterrupt;
tsl256X.Power = true;
while (controller.Read(PinInterrupt) == PinValue.High)
{
    Thread.Sleep(1);
}

Console.WriteLine($"Interrupt detected, read the value to clear the interrupt");
tsl256X.GetRawChannels(out ch0, out ch1);
Console.WriteLine($"Raw data channel 0 {ch0}, channel 1 {ch1}");

Manual integration

You can set a manual integration as well. Be aware that you won't be able to easily calculate an illuminance equivalent. You need to use the manual integration functions offered:

Console.WriteLine("This will use a manual integration for 2 seconds");
tsl256X.StartManualIntegration();
Thread.Sleep(2000);
tsl256X.StopManualIntegration();
tsl256X.GetRawChannels(out ch0, out ch1);
Console.WriteLine($"Raw data channel 0 {ch0}, channel 1 {ch1}");
Product Compatible and additional computed target framework versions.
.NET Framework net is compatible. 
Compatible target framework(s)
Included target framework(s) (in package)
Learn more about Target Frameworks and .NET Standard.

NuGet packages

This package is not used by any NuGet packages.

GitHub repositories

This package is not used by any popular GitHub repositories.

Version Downloads Last Updated
1.2.869 183 4/2/2025
1.2.864 170 4/2/2025
1.2.852 195 3/11/2025
1.2.846 196 3/10/2025
1.2.822 121 2/26/2025
1.2.775 129 2/4/2025
1.2.772 119 2/4/2025
1.2.755 130 1/31/2025
1.2.743 122 1/20/2025
1.2.737 105 1/13/2025
1.2.718 114 12/30/2024
1.2.704 114 12/18/2024
1.2.696 111 12/16/2024
1.2.673 119 10/23/2024
1.2.656 128 10/3/2024
1.2.639 158 9/6/2024
1.2.631 140 8/28/2024
1.2.613 144 8/9/2024
1.2.601 120 7/26/2024
1.2.590 125 7/17/2024
1.2.573 147 6/19/2024
1.2.570 145 6/14/2024
1.2.536 146 4/15/2024
1.2.534 145 4/13/2024
1.2.514 147 3/22/2024
1.2.494 153 2/28/2024
1.2.462 225 1/5/2024
1.2.458 171 12/20/2023
1.2.436 189 11/10/2023
1.2.416 126 11/8/2023
1.2.403 165 10/6/2023
1.2.396 164 9/27/2023
1.2.384 167 9/6/2023
1.2.378 181 8/16/2023
1.2.369 186 8/2/2023
1.2.363 180 7/28/2023
1.2.357 193 7/19/2023
1.2.354 203 7/14/2023
1.2.345 182 6/21/2023
1.2.341 190 6/14/2023
1.2.337 207 6/7/2023
1.2.335 204 6/2/2023
1.2.329 197 5/26/2023
1.2.316 203 5/16/2023
1.2.313 208 5/12/2023
1.2.302 210 5/10/2023
1.2.297 191 5/3/2023
1.2.273 293 3/17/2023
1.2.267 297 3/10/2023
1.2.263 279 3/8/2023
1.2.259 307 2/27/2023
1.2.256 316 2/24/2023
1.2.253 314 2/22/2023
1.2.222 359 1/9/2023
1.2.217 348 1/6/2023
1.2.212 346 1/5/2023
1.2.208 372 1/3/2023
1.2.203 367 12/28/2022
1.2.159 428 11/14/2022
1.2.153 413 11/5/2022
1.2.141 451 10/25/2022
1.2.128 451 10/22/2022
1.2.125 456 10/12/2022
1.2.87 557 9/15/2022
1.2.63 464 9/3/2022
1.2.47 486 8/15/2022
1.2.40 479 8/6/2022
1.2.38 489 8/5/2022
1.2.28 467 8/1/2022
1.2.13 493 7/24/2022
1.2.10 500 7/23/2022
1.1.142.3202 520 7/7/2022
1.1.133.52556 500 6/30/2022
1.1.121.35854 508 6/26/2022
1.1.118.19693 507 6/24/2022
1.1.116.8772 494 6/24/2022
1.1.102.51394 478 6/15/2022
1.1.99.36719 480 6/14/2022
1.1.97.17326 500 6/13/2022
1.1.92.53000 494 6/8/2022
1.1.72.29765 497 5/31/2022
1.1.61.27737 510 5/25/2022
1.1.58.10097 504 5/23/2022
1.1.54.28879 494 5/23/2022
1.1.40 528 5/5/2022
1.1.3 508 4/15/2022
1.1.1 521 4/14/2022
1.0.300 521 4/3/2022
1.0.288-preview.113 169 3/25/2022
1.0.288-preview.107 160 3/24/2022
1.0.288-preview.104 157 3/22/2022
1.0.288-preview.103 160 3/21/2022
1.0.288-preview.99 166 3/18/2022
1.0.288-preview.94 175 3/15/2022
1.0.288-preview.77 176 2/27/2022
1.0.288-preview.75 160 2/26/2022
1.0.288-preview.63 172 2/16/2022
1.0.288-preview.61 172 2/12/2022
1.0.288-preview.58 172 2/10/2022
1.0.288-preview.53 176 2/9/2022
1.0.288-preview.48 188 2/4/2022
1.0.288-preview.41 184 1/31/2022
1.0.288-preview.22 173 1/27/2022
1.0.288-preview.20 185 1/27/2022
1.0.288-preview.18 191 1/27/2022
1.0.272 549 1/10/2022
1.0.260 382 12/10/2021
1.0.259 385 12/9/2021
1.0.258 368 12/7/2021
1.0.231 393 10/27/2021